<LOGO>
FM Transmitter Measurement Report
Created: 2024-09-23 10-54-25
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 60 dBuV INFO
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 5 kHz 17037 0,0470
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
1,7 dBr 2,48 dBr 3,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INFO " F206 0 (No PTY) 1 0 0 0 10:54, 23.09.2024
RT
"10H-12H FRANCEINFO: - LE BRIEF ECO - FRANCEINFO : L'INFO JUSTE. "
AF EON
105.5, 105.7 MHz F222, F201, F202, F203
FM Scope Station: 105.50 MHz, signal: 5/5 (60 dBuV) Max at: 5 kHz MIN: 3 kHz % above 75 kHz: 0,0470 Acquired: 2024/09/23 10:53:22 Total samples: 17037 Equivalent time: 0:14:11 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,9 dBr MIN: 1,7 dBr AVE: 2,48 dBr % above 13,0 dBr: 0,0 Last value: 2,8 dBr (2024/09/23 10:53:20) Station: 105.50 MHz, signal: 5/5 (60 dBuV) 10:42 10:44 10:46 10:48 10:50 10:52 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality